OTK Corporation
Industrial Equpment
Адрес:
Moscow - Almaty - Riga - Baku - Minsk - Erevan - Tbilisi - Bishkek -Tashkent - Ashgabat
Телефон:

SV/E

Vacuum Relief Valve deflagration-proof

Function and Description

csm_4d797881f1b5517b655c618d3f0c887c4a94ef07_7946789ae0 The deflagration-proof SV/E type PROTEGO® valve is a state of the art vacuum relief valve with an integrated flame arrester unit. It is primarily used as a safety device for flame transmission proof inbreathing on tanks, containers and process engineering apparatus. The valve offers reliable protection against vacuum and prevents inbreathing of air almost up to the set pressure; it also protects against atmospheric deflagration. The PROTEGO® flame arrester unit is designed to achieve minimum pressure drop with maximum safety. The PROTEGO® SV/E valve is available for substances from explosion groups IIA to IIC.

When the set vacuum is reached, the valve starts to open and reaches full lift within 10% overpressure. This unique 10% technology enables a set vacuum that is only 10% above the maximum allowable working vacuum (MAWV) of the tank. After years of development, this typical opening characteristic of a safety relief valve is now also available for the low pressure range. The tank pressure is maintained up to the set vacuum with a tightness that is far superior to the conventional standard due to our state of the art manufacturing technology. This feature is ensured by the valve seats made of high quality stainless steel and with individually lapped valve pallets (1) or with an air cushion seal (2) in conjunction with high quality FEP diaphragm. The valve pallets are also available with a PTFE seal to prevent the valve pallets from sticking when sticky products are used and to enable the use corrosive fluids. After the vacuum is equalized, the valve reseats and provides a tight seal.

If the valve is used in atmospheres forming an explosive mixture with air and the mixture ignites, the integrated PROTEGO® flame arrester unit (3) prevents flame transmission into the tank.

The standard design is tested at an operating temperature up to +60°C / 140°F and meets the requirements of European tank design standard EN 14015 – Appendix L and ISO 28300 (API 2000). In addition numerous versions for higher operating temperature are available.

Type-approved in accordance with the current ATEX Directive and EN ISO 16852 as well as other international standards. Additional certificates from classification associations for use on ships are also available.

Features and Advantages

  • requires only 10% overpressure to full lift
  • extreme tightness and hence least possible product losses and reduced environmental pollution
  • through 10% technology lower set vacuum can be reached which results in product loss reduction compared to conventional 40% and 100% overpressure technology vents (compare API 2000)
  • optimized flow performance
  • the valve disc is guided within the housing to protect against harsh weather conditions
  • can be used as protective system according ATEX in areas subject to explosion hazards
  • FLAMEFILTER® provides protection against atmospheric deflagration
  • FLAMEFILTER® integrated into the valve saves space, weight and reduces cost
  • FLAMEFILTER® protected from clogging through product vapour
  • PROTEGO® flame arrester unit has a low pressure drop
  • maintenance friendly design
  • modular design enables individual FLAMEFILTER® and valve pallets to be replaced
  • an additional lifting gear can be purchased

Download

  • Dimensions

    To select the nominal size (DN), please use the flow capacity chart on the following page

    DN 50 / 2'' 80 / 3'' 100 / 4" 150 / 6'' 200 / 8'' 250 / 10'' 300 / 12''
    a 140 / 5.51 170 / 6.69 190 / 7.48 230 / 9.06 300 / 11.81 325 / 12.80 425 / 16.73
    b 105 / 4.13 115 / 4.53 125 / 4.92 165 / 6.50 195 / 7.68 230 / 9.06 280 / 11.02
    c 225 / 8.86 240 / 9.45 320 / 12.60 410 / 16.14 460 / 18.11 525 / 20.67 575 / 22.64
    d 170 / 6.69 235 / 9.25 280 / 11.02 335 / 13.19 445 / 17.52 505 / 19.88 505 / 19.88
    e 215 / 8.46 215 / 8.46 255 / 10.04 345 / 13.58 435 / 17.13 470 / 18.50 635 / 25.00

    Dimensions in mm / inches

    csm_e62a1c3f5986814d48ca987eff15521b430bc6ec_ab030dad04

    csm_33d566b8591b7cf1b806b155a53fa32c82197652_8287b4a04e

    Detail X

    csm_617a2d97aac892825944001eee6024f36b85496b_2e12a3b258

    Detail X  

  • Material selection for housing

    Design   B C
    Housing   Steel Stainless Steel
    Heating jacket (SV / E-(S)-H-...)   Steel Stainless Steel
    Valve seat   Stainless Steel Stainless Steel
    Gasket   PTFE PTFE
    Flame arrester unit   B B

    Special materials upon request

    Material combinations of flame arrester unit

    Design & B
    FLAMEFILTER® cage   Stainless Steel
        Stainless Steel

    Special materials upon request

    Material selection for valve pallet

    Design A B C D E F
    Vacuum range [mbar]
    [inch W.C.]
    -2.0 up to -3.5
    -0.8 up to -1.4
    <-3.5 up to -14
    <-1.4 up to -5.6
    <-14 up to -35
    <-5.6 up to -14
    <-35 up to -60
    <-14 up to -24
    <-14 up to -35
    <-5.6 up to -14
    <-35 up to -60
    <-14 up to -24
    Valve pallet Aluminium Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
    Sealing FEP FEP Metal to Metal Metal to Metal PTFE PTFE

    Special materials and higher pressure settings upon request

    csm_e62a1c3f5986814d48ca987eff15521b430bc6ec_ab030dad04

    csm_33d566b8591b7cf1b806b155a53fa32c82197652_8287b4a04e

    Detail X

    csm_617a2d97aac892825944001eee6024f36b85496b_2e12a3b258

    Detail X

  • Selection of explosion group

    MESG Expl. Gr. (IEC / CEN) Gas Group (NEC)
    ≥ 0,65 mm IIB3 C
    ≥ 0,50 mm IIB B
    < 0,50 mm IIC B

    Special approvals upon request`

    Specification of max. operating temperature

    ≤ 60°C / 140°F Tmaximum allowable operating temperature in °C
    - Designation

    higher operating temperatures upon request

    Flange connection type

    EN 1092-1; Form B1
    ASME B16.5; 150 lbs RFSF

    other types upon request

    Design Types and Specifications

    The valve disc is weight-loaded. Higher vacuum can be achieved upon request with a special spring loaded design.
    There are four different designs:

    Vacuum relief valve, basic design

    SV/E- – - –

    Vacuum relief valve with heating jacket (max. heating fluid temperature +85°C / 185°F)

    SV/E- – - H

    Vacuum relief valve with lifting gear (ship design)

    SV/E- S - –

    Vacuum relief valve with lifting gear (ship design) and heating jacket (max. heating fluid temperature +85°C / 185°F)

    SV/E- S - H

    Additional special devices available upon request

    Settings

    Vacuum:

    -2.0 mbar -60 mbar (-0.2 kPa up to -6 kPa)
      -0.8 inch W.C. -24 inch W.C.  

    Higher vacuum settings upon request

    csm_e62a1c3f5986814d48ca987eff15521b430bc6ec_ab030dad04

    csm_33d566b8591b7cf1b806b155a53fa32c82197652_8287b4a04e

    Detail X

    csm_617a2d97aac892825944001eee6024f36b85496b_2e12a3b258

    Detail X

  • Flow Capacity Chart

    2106ea556881862019ac469678b6d4522b5bf346

    566a220c9ed70f6f5c37d99e8ce7f08c53f09d6f

    8fd1673d70f647166118cf95064dd250da2bebc8

    The flow capacity charts have been determined with a calibrated and TÜV certified flow capacity test rig. Volume flow V in (m³/h) and CFH refer to the standard reference conditions of air ISO 6358 (20°C, 1bar). Conversion to other densities and temperatures refer to Vol. 1: “Technical Fundamentals”.

    csm_e62a1c3f5986814d48ca987eff15521b430bc6ec_ab030dad04

    csm_33d566b8591b7cf1b806b155a53fa32c82197652_8287b4a04e

    Detail X

    csm_617a2d97aac892825944001eee6024f36b85496b_2e12a3b258

    Detail X

Download
Телефон:
Feedback

Leave a request and we will contact you as soon as possible