Pressure Relief Valve in heat jacketed design
Function and Description
The SD/BS-H type PROTEGO® valve is a highly developed pressure relief valve with a heating jacket down to the flange. It is primarily used as pressure relief device for vessels and process engineering equipment under difficult operating conditions. This includes extreme weather conditions or products that tend to form polymers at certain temperatures, adhere, or form deposits that negatively influence function (such as bitumen, tar, dust). The valve offers reliable protection against overpressure and prevents the unacceptable loss of product vapors close to the set pressure.
The device will start to open as soon as the set pressure is reached and only requires 10% overpressure to full lift. Continuous investments into research and development have allowed PROTEGO® to develop a low pressure valve which has the same opening characteristic as a high pressure safety relief valve. This “full lift type” technology allows the valve to be set just 10% below the maximum allowable working pressure of the tank and still safely vent the required mass flow.
Due to our highly developed manufacturing technology the tank pressure is maintained up to set pressure, with a tightness that is far superior to the conventional standard. This feature is achieved by valve seats made of high-grade stainless steel with precisely lapped valve pallets and a reinforced housing design. After the excess pressure is discharged, the valve reseats and provides a tight seal again.
Features and Advantages
- “full lift type” technology valve utilizes only 10% overpressure to reach full lift
- extreme tightness and hence least possible product losses and reduced environmental pollution
- set pressure is close to the opening pressure which results in best possible pressure management of the system
- high flow capacity
- the valve pallet is guided within the housing to protect against harsh weather conditions
- can be used in areas subject to an explosion hazard
- heating jacketed design down to the flange to avoid cold bridges
- maximum permissible heating medium temperature of 320°C / 608°F (at 6 bar / 87 psi)
- a special design with a heatable valve cover is available
- at low pressure settings, an optimized valve pallet cover prevents the set pressure from being distorted by dust or condensate
- reinforced housing design
- a special design with a mechanical vent pallet lift device is available
-
Dimensions
To select the nominal size (DN), use the flow capacity chart on the following page
DN1 DN2 a b b c d d e bis 30 mbar > 30 mbar bis 30 mbar > 30 mbar 80 / 3" 15 / ½" 325 / 12.80 400 / 15.75 515 / 20.28 70 / 2.76 250 / 9.84 390 / 15.35 250 / 9.84 100 / 4" 15 / ½" 325 / 12.80 400 / 15.75 505 / 19.88 60 / 2.36 250 / 9.84 380 / 14.96 250 / 9.84 150 / 6" 15 / ½" 405 / 15.94 460 / 18.11 595 / 23.43 60 / 2.36 315 / 12.40 470 / 18.50 290 / 11.42 200 / 8" 15 / ½" 510 / 20.08 470 / 18.50 575 / 22.64 65 / 2.56 305 / 12.01 445 / 17.52 340 / 13.39 Dimensions in mm / inches * also available with special flange DN 50 / 2''

-
Material selection for housing
Design A B Housing Steel Stainless Steel Heating Jacket Steel Stainless Steel Valve Seat Stainless Steel Stainless Steel Special materials upon request
Material selection for pressure valve pallet
Design A B C Pressure range [mbar]
[inch W.C.]+5,0 up to +25
+2 up to +10>+10 up to +30
>+4 up to +12>+30 up to +210
>+12 up to +84Valve pallet Aluminium Stainless Steel Stainless Steel Valve pallet hood Stainless Steel Stainless Steel - Sealing Metal to Metal Metal to Metal Metal to Metal Special materials and devices with higher set pressure or vacuum are available upon request

-
Flange connection type
EN 1092-1; Form B1 ASME B16.5; 150 lbs RFSF other types upon request
Design Types and Specifications
The valve pallet is weight-loaded. Starting at a set pressure of 30 mbar, a vane guide is also used.
Pressure valve in basic design with heating jacket SD/BS - H
Additional special devices available upon request.
Settings
Pressure:
+5.0 mbar +210 mbar +2.0 inch W.C. +84 inch W.C. Higher pressure settings upon request.

-
Flow Capacity Chart

The flow capacity charts have been determined with a calibrated and TÜV certified flow capacity test rig. Volume flow V in (m³/h) and CFH refer to the standard reference conditions of air ISO 6358 (20°C, 1bar). Conversion to other densities and temperatures refer to Vol. 1: “Technical Fundamentals”.